Abstract
Abstract The objective was to find a nonintrusive technique for determining the gas content of an insulated glass window unit. During this study, first measurements of the electric breakdown field for air-argon mixtures were obtained. The breakdown field does not depend strongly on whether the electrodes are plain window glass or glass with low emissivity coatings, nor does it depend on the glass electrode spacing. Our reported strong variation of the breakdown field with admixtures of air to the argon gas suggests that this approach could provide an inexpensive nonintrusive gas analysis for insulated glass window units with an ultimate precision of 0.1% on the argon content.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.