Abstract

We propose a new non-intrusive flow measurement method using the distributed feedback fiber laser (DFB-FL) as a sensor to monitor flow in the pipe. The relationship between the wavelength of the DFB-FL and the liquid flow rate in the pipeline is derived. Under the guidance of this theory, the design and test of the flow sensor is completed. The response curve is relatively flat in the frequency range of 10 Hz to 500 Hz, and the response of the flow sensor has high linearity. The flow from 0.6 m3/h to 25.5 m3/h is accurately measured under the energy analysis method in different frequency intervals. A minimum flow rate of 0.046 m/s is achieved. The experimental results demonstrate the feasibility of the new non-intrusive flow measurement method based on the DFB-FL and accurate measurement of small flow rates.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.