Abstract

An on‐line method is developed for monitoring of mean particle size in fluidized beds using pressure fluctuations (PFs) and acoustic emissions (AE) signal by recurrence plot (RP) and recurrence quantification analysis (RQA). PFs and AE signals of a lab‐scale fluidized bed were measured simultaneously at various superficial gas velocities and mean particle sizes. Although the AE signals are often very complicated due to many different acoustic sources in the bed, applying RP analyses showed that small changes in mean particle size can be detected by visual comparison of AE‐RP structures, while this cannot be distinguished by graphical RP analysis of PFs. Moreover, the hydrodynamics of the bed was inspected through RQA analysis of both signals. For this purpose, recurrence rate, determinism, laminarity, average length of diagonal and vertical lines were extracted from RPs showing the effect of an increase in the mean particle size. © 2016 American Institute of Chemical Engineers AIChE J, 62: 3547–3561, 2016

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call