The performance of a non-ideal explosive has been investigated in a reinforced concrete 2-room test structure with two different window and door configurations: (1) without and (2) with doors and a window. Pressure records at different locations of the two-room test structure for the two different configurations have been compared with each other and 3D CFD numerical simulations. Reaction efficiencies of fuel gases and aluminum particles in the explosive detonation products, especially the aerobic reaction with air, as functions of time have been estimated for the two cases and then compared with each other.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.