Abstract
Shielding techniques are widely applied in suppression of near electric field interference from power converters, so as to enhance their electromagnetic compatibility (EMC) performance. However, sometimes traditional shielding method cannot effectively suppress the electromagnetic interference (EMI) in the full frequency range. In order to make a power converter meet the limit requirement of EMC standard, this paper proposes an improved non-ideal electric field shielding method to balance the suppression effects of the low frequency and high frequency interference. A resistor with appropriate resistance is connected between the shielding layer and the reference ground so as to balance the suppression effect of the high frequency and the low frequency interference. The EMI measurement results show that the power converter with improved shielding method had good EMC performance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.