Abstract

BackgroundSkin patch testing is still seen as the gold standard for the diagnosis of allergic hypersensitivity. For several metals and for patients with a suspected adverse reaction to their medical device implant material, patch testing can be unreliable. The current alternative to metal allergy patch testing is the in vitro lymphocyte proliferation test (LPT) using tritiated thymidine. This method is well‐established but requires handling of radioactive material, often uses heat‐inactivated allogenic human pooled serum and cannot determine T cell subsets.ObjectiveTo develop a radioactive free LPT by using carboxyfluorescein succinimidyl ester (CFSE) and to evaluate the influence of serum source (heat‐inactivated human pooled serum [HI HPS] vs autologous serum) on the sensitivity and specificity of the nickel‐specific LPT.MethodsPeripheral blood mononuclear cells derived from nickel‐allergic patients and healthy controls were collected, labelled with CFSE and cultured in medium containing 10% HI HPS or 10% autologous serum with or without additional T cell skewing cytokine cocktails (Th1: IL‐7/IL‐12, Th2: IL‐7/IL‐4 or Th17: IL‐7/IL‐23/IL‐1β) in the absence or presence of NiSO4. The stimulation index (SI) was calculated as the ratio of divided cells, that is the percentage of CFSElow/neg CD3+CD4+ T‐lymphocytes upon nickel stimulation compared to the percentage of CFSElow/neg CD3+CD4+ T‐lymphocytes without antigen. These results were compared with the history of Ni allergy, patch test results and the MELISA test.ResultsAutologous serum positively influenced Ni‐specific proliferation while HI HPS negatively influenced Ni‐specific proliferation. The test protocol analysing CD4+ cells and autologous serum without skewing cytokines scored the best diagnostic values (sensitivity 95%; specificity 93%; and overall accuracy 94%) compared to the parallel test using HI HPS (accuracy 60%). Cytokine supplements did not further improve the test protocol which used autologous serum. The protocol using HI HPS could be further improved by addition of the cytokine skewing cocktails.ConclusionsHere, we describe an optimized and highly accurate flow cytometric LPT which comprises of CFSE‐labelled cells cultured in autologous serum (not heat inactivated) and without the presence of T cell skewing cytokines.Clinical relevanceThe sensitivity and specificity of LPT is enhanced, compared to HI HPS, when autologous serum without skewing cytokines is used.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.