Abstract

99m Tc-MAG3 diuresis renography is a noninvasive functional imaging technique used to assess clearance of radiotracer in a dilated urinary tract under high diuresis. It is commonly performed in patients to diagnose functionally significant urinary tract obstruction. In some pediatric patients, sedation is required to enable imaging. However, propofol, a commonly used IV sedative agent, is associated with altered renal hemodynamics. We report a case series of 3 pediatric patients at our institution who received propofol sedation to enable 99m Tc-MAG3 diuresis renography using a F+0 protocol, outlining that some "abnormal" studies were in fact assessed to be nondiagnostic.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.