Abstract

Magnetic flux leakage (MFL) testing is effective in detecting internal defects in ferromagnetic materials. However, it requires the saturation magnetization of materials, which is not always practicable in complex inspection environments. Therefore, this study presents a novel dynamic permeability testing (DPT) method, in which internal defects will induce dynamic permeability variations on the surface of weakly magnetized ferromagnetic materials, and the variations are then detected by alternating current detection coils with magnetic cores, enabling the identification of internal defects. The principle of DPT is analyzed through simulations, which are subsequently verified by experiments. Furthermore, the effects of excitation frequency, probe lift-off, and defect size on the DPT signal are investigated experimentally. Finally, the comparison with conventional MFL demonstrates that the DPT method can effectively identify the internal defect using a weak magnetization current of 0.1 A (about 0.25 T in the steel plate), whereas MFL requires 0.5 A (about 1.32 T) to achieve a similar detection capability under the same probe lift-off values. This new method has significant practical value, especially in situations where saturation magnetization is not feasible.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call