Abstract

An inductive method to detect a third harmonic voltage V/sub 3/ is widely used to measure critical current densities J/sub c/ of large-area superconducting films. Very recently Mawatari et al. have elucidated the generation mechanism of V/sub 3/ and derived the relationship between the coil ac current and V/sub 3/. We have supported this theory by experiment, and then used this method to measure J/sub c/ of YBCO films in dc magnetic fields at various temperatures (0-5 T, 66-77.3 K). The temperature and the field dependence of J/sub c/ was in good agreement with those measured by dc magnetization and transport measurement. It is demonstrated that this method can also be applicable to measure J/sub c/ in applied dc magnetic fields.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.