Abstract
Nondestructive evaluation of formability (r-value) in cold-rolled steel sheet with an electromagnetic acoustic transducer (EMAT) for the fundamental shear horizontal plate wave (SH0-wave) has been developed. First, the principle of nondestructive r-value measurement is described. Next the characteristics of the magnetostrictive type EMAT and the Lorenz force type EMAT for the SH0-wave were evaluated to permit an optimum sensor for nondestructive measurement. Based on the results, the system with the magnetostrictive type EMAT was fabricated and the capability for measuring r-values was evaluated using many samples. The system was confirmed to measure r-values with an accuracy of 1σ=0.065 nondestructively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.