Abstract

Non-contact geomagnetic anomaly detection, as one of passive non-destructive testing (NDT) techniques, can be used to locate pipeline defects, while its accuracy is affected by random noise and detection orientation. In order to extract effective geomagnetic anomaly signals of pipeline defects, a method based on empirical mode decomposition (EMD) and magnetic gradient tensor was studied. In order to filter random noise, EMD was performed to self-adaptively decompose magnetic field signals into a series of intrinsic mode functions (IMFs), and then Hurst exponent was implemented to exclude false modes; The calculation method of magnetic gradient tensor modulus (MGTM) was proposed to obtain precise defect locations according to tensor symmetry; Subsequently, the remote pipeline defect model was built based on the magnetic dipole theory, and the relationship between detection orientation and MGTM was discussed. The experimental results showed that the proposed method could realize high precision and reliable non-contact geomagnetic localization of pipeline defects.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.