Abstract

A non-contact and direct electrocaloric effect (ECE) measurement system was developed for rapid ECE measurement. The ECE of ferroelectric materials was measured directly using two measurement methods, namely, the constant heating rate method (CH method) and one-dimensional temperature gradient method (1D method), with the measurement system. The CH method continuously measures the ECE while gently heating the sample, and it can evaluate the performance of the sample more quickly than conventional methods that measure the ECE at steady state. The 1D method directly measures the ECE using a 1D temperature distribution applied to the sample. This method can measure the temperature dependence of the ECE faster than the CH method. The measurement system achieved a high signal-to-noise ratio, and the temperature dependence of the ECE measured by the two methods was consistent. The proposed measurement system and methods enable promising candidate materials for electrocaloric cooling systems to be screened more rapidly than when using conventional approaches.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.