Abstract

Cultured 9L cells were incubated with varying concentrations of pheophorbide-a-hexyl ether (HPPH) and then exposed to 665-nm red light from a non-coherent light source or a dye laser. Cell death was produced by both light sources, with the non-coherent light being most effective at the highest HPPH concentrations. To assess the feasibility of using the non-coherent light source for clinical photodynamic therapy (PDT), four dogs and three cats presenting with spontaneous superficial tumours were injected intravenously with 0.15 mg kg(-1) of HPPH, 1 h before their tumours were irradiated with 665-nm non-coherent light (50 mW cm(-2), 100 J cm(-2)). Of the nine tumours treated, there were eight complete responses, all occurring in animals with squamous cell carcinoma. After 68 weeks of follow-up, the median initial disease-free interval had not been reached. These data suggest that non-coherent light sources may be efficacious for photodynamic therapy of spontaneous superficial tumours in animals, representing a cost-effective alternative to medical lasers in both veterinary and human oncology.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call