Abstract

Abstract One of the currently investigated problems in power electronics-based electrical energy conversion is proper operation of electronic converters during grid voltage imbalance and harmonics. In classic control methods, it introduces oscillations of variables, resulting in the necessity to improve control systems with signals filtration and usually by application of resonant terms as part of current controllers. The paper presents a new approach to grid-connected inverter control based on transformation to a non-Cartesian frame, the parameters of which are correlated with grid voltage asymmetry. The proposed method results in resignation from resonant terms used as controllers and their replacement with proportional–integral terms for which anti-wind-up structures are significantly simpler than for oscillatory terms. The paper presents new transformation principles, features and some simulation results showing the waveforms of signals transformed to the new non-Cartesian frame.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.