Abstract

To investigate the value of nonabsorbable sutures in reducing the incidence of consecutive exotropia after large, "hang-back" medial rectus recessions. The medical records of patients who underwent medial rectus recession of ≥6.5mm in individuals ≤2years of age, or ≥7.0mm in those >2years were retrospectively reviewed. Patients were divided into two groups based on suture material used: absorbable, polyglactin 910 sutures (44 patients); nonabsorbable, polyester sutures (50 patients). Preoperative measurements, ductions, strabismus surgery, and postoperative results were analyzed. Inadequate anchoring of the medial rectus muscle was suspected when consecutive exotropia developed 4-7weeks after surgery after initial satisfactory alignment and was confirmed if during reoperation the medial rectus muscle appeared recessed >2mm beyond the originally intended recession. Consecutive exotropia due to inadequate anchoring of the medial rectus muscle occurred in 11 of 66 muscles (17%) in the absorbable suture group. The muscle was found 6-10mm posterior to the intended recession. Limited duction in the field of action of the involved medial rectus muscle occurred in 9 of the 11 muscles (82%). None of the eyes with nonabsorbable sutures showed inadequate anchoring. The incidence of consecutive exotropia was higher in the absorbable suture group (30%) than in the nonabsorbable suture group (6%) (P<0.005). Using nonabsorbable suture for large, hang-back medial rectus recessions greatly reducesthe incidence of consecutive exotropia that can occur when absorbable suture dissolves.