Abstract
Humanized monoclonal antibody produced by mammalian cell culture may contain significant amounts of antibody dimers and smaller amounts of higher order aggregates. These are undesirable in therapeutic formulations, and their content should be lower than specific allowable limits. Quantitative analysis of aggregate content is usually carried out by size exclusion chromatography (SEC), which is slow and often gives poorly resolved peaks. We describe a novel hydrophobic interaction membrane chromatography-based technique for rapid, non-size-based separation and analysis of the aggregate content in monoclonal antibody samples. The typical sample analysis time using this technique is less than 3 min, this being significantly faster than SEC. The technique gives excellent resolution of the antibody, its dimer, and higher order aggregates and could potentially be scaled up for large-scale manufacture of aggregate-free monoclonal antibody. This work also clearly shows that monoclonal antibody aggregates are more hydrophobic than the monomer form, a fact that could have significant theoretical and practical implications.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.