Abstract

A single-shot electro-optic (EO) diagnostic has been installed on the ELYSE photocathode RF gun accelerator to monitor the electron bunch at the place and under the conditions of the ps pulse radiolysis experiments. The EO signal is due to the coulombic field of the electron bunch and to a contribution of a free-space THz radiation generated by the same electron pulse. This signal is recorded shot-to-shot at the repetition rate of the accelerator. The jitter of the arrival time of the electron bunch is characterized for the first time with a non-invasive method and is confirmed to be around 1 ps.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.