Abstract
Optimization of cerebral blood flow (CBF) is the cornerstone of clinical management in a number of neurologic diseases, most notably ischemic stroke. Intrathoracic pressure influences cardiac output and has the potential to impact CBF. Here, we aim to quantify cerebral hemodynamic changes in response to increased respiratory impedance (RI) using a non-invasive respiratory device. We measured cerebral perfusion under varying levels of RI (6 cm H2O, 9 cm H2O, and 12 cm H2O) in 20 healthy volunteers. Simultaneous measurements of microvascular CBF and middle cerebral artery mean flow velocity (MFV), respectively, were performed with optical diffuse correlation spectroscopy and transcranial Doppler ultrasound. At a high level of RI, MFV increased by 6.4% compared to baseline (p = 0.004), but changes in cortical CBF were non-significant. In a multivariable linear regression model accounting for end-tidal CO2, RI was associated with increases in both MFV (coefficient: 0.49, p < 0.001) and cortical CBF (coefficient: 0.13, p < 0.001), although the magnitude of the effect was small. Manipulating intrathoracic pressure via non-invasive RI was well tolerated and produced a small but measurable increase in cerebral perfusion in healthy individuals. Future studies in acute ischemic stroke patients with impaired cerebral autoregulation are warranted in order to assess whether RI is feasible as a novel non-invasive therapy for stroke.
Highlights
Optimization of cerebral blood flow (CBF) is a cornerstone of clinical management for a number of neurological diseases that result in impaired oxygen delivery to the brain, most notably ischemic stroke
Vascular risk factors were uncommon in the cohort: 10% had hypertension, 15% hyperlipidemia, 10% asthma, and no subjects had diabetes or coronary artery disease
No subjects elected to terminate the protocol before completion, and there were no documented episodes of hypoxia, hypoventilation, or hyperventilation
Summary
Optimization of cerebral blood flow (CBF) is a cornerstone of clinical management for a number of neurological diseases that result in impaired oxygen delivery to the brain, most notably ischemic stroke. A respiratory device incorporating a one-way valve that provides resistance only during the inspiratory component of the respiratory cycle, referred to as respiratory impedance (RI), leads to augmentation of the inspiratory effort in order to generate enough negative intrathoracic pressure to Respiratory Impedance Enhances Cerebral Perfusion overcome the impedance. This device has typically been used for respiratory muscle training, but the effect on cerebral perfusion in humans is not well studied. The limited data that exist have focused on patients with orthostatic hypotension, where RI has been shown to increase CBF velocity [measured by transcranial Doppler (TCD)] [1], and reduce subjective symptoms [1, 8]
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.