Abstract

An appropriate pH level is an important prerequisite for the physiologal functioning of cells and tissues. Changes in the extracellular pH often lead to specific cellular reactions and an altered metabolism of cells and tissues influences the extracellular pH range. Thus a method to monitor the extracellular pH is a valuable tool to track specific tissue reactions. In this article we describe a method for the determination of the pH range adjacent to degradable biomaterials using wireless in vivo imaging. Using hairless but immunocompetent mice the fluorophor 5-(6)-carboxy SNARF-1 and the in vivo fluorescence and multispectral acquisition and analysis system Maestro it is possible to track shifts in pH in small living animals over a longer period of time. This method is especially suitable for studies which focus on the interaction of degrading biomaterials with their adjacent tissues.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.