Abstract

BackgroundKinetic analysis of dynamic PET data requires an accurate knowledge of available PET tracer concentration within blood plasma over time, known as the arterial input function (AIF). The gold standard method used to measure the AIF requires serial arterial blood sampling over the course of the PET scan, which is an invasive procedure and makes this method less practical in clinical settings. Traditional image-derived methods are limited to specific tracers and are not accurate if metabolites are present in the plasma.ResultsIn this work, we utilise an image-derived whole blood curve measurement to reduce the computational complexity of the simultaneous estimation method (SIME), which is capable of estimating the AIF directly from tissue time activity curves (TACs). This method was applied to data obtained from a serotonin receptor study (11C-SB207145) and estimated parameter results are compared to results obtained using the original SIME and gold standard AIFs derived from arterial samples. Reproducibility of the method was assessed using test-retest data. It was shown that the incorporation of image-derived information increased the accuracy of total volume of distribution (V T) estimates, averaged across all regions, by 40% and non-displaceable binding potential (BP ND) estimates by 16% compared to the original SIME. Particular improvements were observed in K1 parameter estimates. BP ND estimates, based on the proposed method and the gold standard arterial sample-derived AIF, were not significantly different (P=0.7).ConclusionsThe results of this work indicate that the proposed method with prior AIF information obtained from a partial volume corrected image-derived whole blood curve, and modelled parent fraction, has the potential to be used as an alternative non-invasive method to perform kinetic analysis of tracers with metabolite products.

Highlights

  • Kinetic analysis of dynamic positron emission tomography (PET) data requires an accurate knowledge of available PET tracer concentration within blood plasma over time, known as the arterial input function (AIF)

  • We have previously shown with simulated 18F-FDG data that the performance of the simultaneous estimation method (SIME) method can be significantly improved if some prior information about the early part of the AIF can be included from another source, such as an image-based measurement or an MRI-derived AIF [10]

  • Throughout this section, the original SIME with no prior information is referred to as SIMEoriginal, the constrained method with prior image-derived information is referred to as SIMEconstrained and the AIF derived from metabolitecorrected arterial samples is referred to as AIFsamples

Read more

Summary

Introduction

Kinetic analysis of dynamic PET data requires an accurate knowledge of available PET tracer concentration within blood plasma over time, known as the arterial input function (AIF). Kinetic analysis methods are often used to extract quantitative measurements from positron emission tomography (PET) scans, such as cerebral blood flow, metabolism and receptor distribution The majority of these methods require a precise knowledge of the arterial input function (AIF) to obtain the concentration of the available PET tracer in the blood plasma. The gold standard method to measure the AIF is arterial blood sampling which involves serial blood sampling from a radial artery during the course of the scan These samples are analysed to determine the concentration of the PET tracer in blood plasma over time.

Objectives
Methods
Results
Conclusion