COPD is the most common reason for hypercapnia. However, it is -by far- not the only reason. In fact, numerous neuromuscular disorders (not only ALS) as well as restrictive thoracic disorders do also lead to clinically highly relevant hypercapnia. Early diagnosis of hypercapnic ventilatory failure usually takes place at nighttime. NIV devices work with a periodic interplay of alternating IPAP and EPAP which results in a ventilation of the lungs, thereby elimination CO2 to treat hypercapnic respiratory failure. Firstline settings for a NIV therapy to treat "stable hypercapnia" are as follows: Pressure Support Ventilation Modus, EPAP 5 cmH2O, IPAP 15 cmH2O, Back Up rate 15/Minute. The overall goal of NIV treatment is a successful reduction in CO2. This can be achieved by changing the following variables of the ventilator settings: increase in IPAP ± increase in back up respiratory rate ± use of assisted pressure controlled ventilation mode (APCV).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.