BackgroundThe aim of this study is to assess the accuracy and feasibility of left ventricular systolic function determined by four-dimensional echocardiography (4DE).MethodsLatex balloons were sewn into the left ventricle (LV) of 20 freshly harvested pig hearts which were then passively driven by a pulsatile pump apparatus. Global longitudinal strain (GLS), global circumferential strain (GCS), global area strain (GAS) and left ventricular ejection fraction (LVEF) derived from 4DEand two-dimensional echocardiography (2DE)-derived LVEF were quantified at different stroke volumes (SV) 30–70 ml and correlated with sonomicrometry data.ResultsIn all comparisons, GLS, GCS, GAS, 2DE-LVEF, and 4DE-LVEF demonstrated strong correlations with sonomicrometry data (r = 0.77, r = 0.89, r = 0.79, r = 0.93, r = 0.96, all P <0.001). Bland-Altman analyses showed slight overestimations of echo-derived GLS, GCS, 2DE-LVEF and 3DE-LVEF over sonomicrometry values (bias = 2.88, bias = 3.99, bias = 3.37, bias = 2.78, respectively). Furthermore, there is better agreement between GCS, 4D LVEF and sonomicrometry values compared with GLS and 2D LVEF.ConclusionFour-dimensional echocardiography accurately assesses LV function. GCS derived by 4DE is a potential alternative parameter to quantify LV systolic function.

Highlights

  • Left ventricular (LV) systolic function is an important predictor of cardiac mortality and morbidity and often is used to select patients for surgical and pharmacological treatment [1,2]

  • Global longitudinal strain (GLS), global circumferential strain (GCS), global area strain (GAS) and left ventricular ejection fraction (LVEF) derived from 4DEand two-dimensional echocardiography (2DE)derived LV ejection fraction (LVEF) were quantified at different stroke volumes (SV) 30–70 ml and correlated with sonomicrometry data

  • There is better agreement between GCS, 4D LVEF and sonomicrometry values compared with global longitudinal strain (GLS) and 2D LVEF

Read more

Summary

Methods

Citation: Chen R, Zhu M, Sahn DJ, Ashraf M (2016) Non-Invasive Evaluation of Heart Function with FourDimensional Echocardiography. PLoS ONE 11(5): e0154996. doi:10.1371/journal.pone.0154996 Latex balloons were sewn into the left ventricle (LV) of 20 freshly harvested pig hearts which were then passively driven by a pulsatile pump apparatus. Global longitudinal strain (GLS), global circumferential strain (GCS), global area strain (GAS) and left ventricular ejection fraction (LVEF) derived from 4DEand two-dimensional echocardiography (2DE)derived LVEF were quantified at different stroke volumes (SV) 30–70 ml and correlated with sonomicrometry data.

Results
Introduction
Materials and Methods
Discussion
Limitations
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call