Abstract

The gold standard for measuring the partial pressure of carbon dioxide remains arterial blood gas (ABG) analysis. For patients with cystic fibrosis undergoing general anesthesia or polysomnography studies, continuous non-invasive carbon dioxide monitoring may be required. The current study compares end-tidal (ETCO2), transcutaneous (TCCO2), and capillary blood gas carbon dioxide (Cap-CO2) monitoring with the partial pressure of carbon dioxide (PaCO2) from an ABG in patients with cystic fibrosis. Intraoperatively, a single CO2 value was simultaneously obtained using ABG (PaCO2), capillary (Cap-CO2), TCCO2, and ETCO2 techniques. Tests for correlation (Pearson's coefficient) and agreement (Bland-Altman analysis) were performed. Data were further stratified into two subgroups based on body mass index (BMI) and percent predicted forced expiratory volume in 1s (FEV1%). Additionally, the absolute difference in the TCCO2, ETCO2, and Cap-CO2 values versus PaCO2 was calculated. The mean ± SD differences were compared using a paired t test while the number of times the values were ≤ 3mmHg and ≤ 5mmHg from the PaCO2 were compared using a Fishers' exact test. The study cohort included 47 patients (22 males, 47%) with a mean age of 13.4 ± 7.8years, median (IQR) BMI of 18.7kg/m2 (16.7, 21.4), and mean FEV1% of 87.3 ± 18.3%. Bias (SD) was 4.8 (5.7) mmHg with Cap-CO2 monitoring, 7.3 (9.7) mmHg with TCCO2 monitoring, and 9.7 (7.7) mmHg with ETCO2 monitoring. Although there was no difference between the degree of bias in the population as a whole, when divided based on FEV1% and BMI, there was greater bias with ETCO2 in patients with a lower FEV1% and a higher BMI. The Cap-CO2 vs. PaCO2 difference was 5.2 ± 5.3mmHg (SD), with 16 (48%) ≤ 3mmHg and 20 (61%) ≤ 5mmHg from the ABG value. The TCCO2-PaCO2 difference was 9.1 ± 7.2mmHg (SD), with 11 (27%) ≤ 3mmHg and 15 (37%) ≤ 5mmHg from the ABG value. The ETCO2-PaCO2 mean difference was 11.2 ± 7.9mmHg (SD), with 5 (12%) ≤ 3mmHg and 11 (26%) ≤ 5mmHg from the ABG value. While Cap-CO2 most accurately reflects PaCO2 as measured on ABG, of the non-invasive continuous monitors, TCCO2 was a more accurate and reliable measure of PaCO2 than ETCO2, especially in patients with worsening pulmonary function (FEV1% ≤ 81%) and/or a higher BMI (≥ 18.7kg/m2).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.