Abstract
Water in biological structures often displays non-Gaussian diffusion behavior. The objective of this study was to test the feasibility of non-Gaussian fitting by using the kurtosis model of the signal intensity decay curves obtained from DWI by using an extended range of b-values in studies of phantoms and HNSCC. Seventeen patients with HNSCC underwent DWI by using 6 b-factors (0, 50-1500 s/mm(2)) at 1.5T. Monoexponential (yielding ADC(mono)) and non-Gaussian kurtosis (yielding apparent diffusion coefficient D(app) and apparent kurtosis coefficient K(app)) fits were performed on a voxel-by-voxel basis in selected regions of interest (primary tumors, metastatic lymph nodes, and spinal cord). DWI studies were also performed on phantoms containing either water or homogenized asparagus. To determine whether the kurtosis model provided a significantly better fit than did the monoexponential model, an F test was performed. Spearman correlation coefficients were calculated to assess correlations between K(app) and D(app). The kurtosis model fit the experimental data points significantly better than did the monoexponential model (P < .05). D(app) was approximately twice the value of ADC(mono) (eg, in neck nodal metastases D(app) was 1.54 and ADC(mono) was 0.84). K(app) showed a weak Spearman correlation with D(app) in a homogenized asparagus phantom and for 44% of tumor lesions. The use of kurtosis modeling to fit DWI data acquired by using an extended b-value range in HNSCC is feasible and yields a significantly better fit of the data than does monoexponential modeling. It also provides an additional parameter, K(app), potentially with added value.
Highlights
AND PURPOSE: Water in biological structures often displays non-Gaussian diffusion behavior
These microstructural changes affect the motion of water molecules, and alter the water diffusion properties and the MR imaging signal intensity
The signal intensity loss in DWI can be quantified by using the ADC, which is a measure of the average molecular motion that is affected by cellular organization and integrity
Summary
The objective of this study was to test the feasibility of non-Gaussian fitting by using the kurtosis model of the signal intensity decay curves obtained from DWI by using an extended range of b-values in studies of phantoms and HNSCC The objective of this study was to test the feasibility of nonGaussian fitting by using the kurtosis model of the signal intensity decay curves obtained from DWI by using an extended range of b-values in studies of phantoms and HNSCC
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.