Abstract

Abstract Several inspection methods can be used to assess the corrosion state of steel reinforcement in concrete. Especially for periodical field surveys and monitoring, non-destructive testing (NDT) methods are to be preferred as they do not cause any or very limited damage to the existing concrete. In this paper, the corrosion state of three reinforced concrete beams exposed to marine environment for 25 years was evaluated by measuring three parameters; electrochemical potential, concrete resistivity and corrosion rate. The measurements were performed with commercial devices. It was found that all devices are applicable for field inspections. Among the methods selected for the study, the electrochemical potential measured in a fine grid and analysed statistically offered the best possibility of evaluating the corrosion state; preferably in combination with selected excavations for determination of the level of corrosion.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.