This paper examined the validity of electromagnetic radiation test to find an internal loss in columns of Japanese traditional wooden temple, Kiyomizu, in Kyoto. First, the test was performed for the specimen. The results showed that the test was able to detect 10cm over internal loss. Secondly, the test was performed for the column of Kiyomizu and some deteriorated columns were found. Finally, the earthquake response analysis was conducted for the Kiyomizu model which was assumed internal loss. In the result, the internal loss which exist column bottoms has minor influence on the seismic performance of Kiyomizu.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.