Abstract

This works aims to show the feasibility of using low-intensity ultrasound (US) to predict the salt content in brined Biceps femoris (BF) and Longissimus dorsi (LD) pork muscles. For this purpose, meat samples were salted in brine solution (20% w/w at 2°C) for different times (24, 48, 96 and 168h) and the US velocity measured before and after salting. In addition, model samples with preset water and salt contents were formulated and the US velocity was measured. In the model samples, the salt content (XS) had a more marked effect on the US velocity (13.0m/s per ΔXS=1% wet basis) than the water content (5.0m/s per ΔXW=1% wet basis). The salt gain and the water loss during brining caused the US velocity to increase (61.5 and 49.3m/s for 168h in LD and BF, respectively). Significant linear relationships between the US velocity and both factors (XS and XW) were established (R2>0.771). A predictive model of the salt content based on the US velocity was proposed; this was successfully validated (average estimation error 0.48%), which shows the feasibility of using US for industrial quality control purposes.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.