Abstract

Insufficient supply of oxygen (O2) to the cathode Pt catalyst layer can be caused by transport resistance, and is a major problem in proton exchange membrane fuel cells. To clarify O2 transport phenomena, a non-destructive technique for measuring the O2 concentration is required. In this study, the O2 concentration at the catalyst layer was measured under operating conditions, using a tiny optical fiber and oxygen indicator. The O2 concentration decreased continuously with decreasing cell voltage. It was considered that a decrease in size of the reaction area was caused by water accumulation under the rib. Local O2 concentration measurements suggested that power generation was concentrated at the channel region.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.