MicroRaman measurements have been performed on a commercially available plasma sprayed hydroxyapatite-coated titanium implant. A double-band structure in the ν 1 vibration mode was clearly identified and attributed to the presence of β-tricalcium phosphate at the metal substrate–hydroxyapatite interface. β-tricalcium phosphate probably results from the specific crystallization mode of the molten hydroxyapatite particles due to rapid cooling during the plasma spray process. The presence of β-tricalcium phosphate can explain the dissolution of the hydroxyapatite coating when exposed to the body fluid for a long period of time due to the high solubility of β-tricalcium phosphate in acidic medium.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.