Abstract

We investigated the potential of front-face synchronous fluorescence spectroscopy (△λ = 75 nm) to non-destructively evaluate beef freshness and quality decline during chilled storage. The total volatile basic nitrogen (TVB-N), thiobarbituric acid reactive substances (TBARS) and total viable count (TVC) values were used as standard freshness indicators. The fluorescent substances, including amino acids, collagen and conjugated Schiff bases, were highly correlated with the chemical and microbial deterioration of the beef. Quantitative models for simultaneously predicting the three freshness indicators were built combined with partial least squares (PLS) algorithm and showed good reliability. For TVB-N and TBARS values, Rc2 and Rp2 were both above 0.900, and for TVC values Rc2 and Rp2 were 0.912 and 0.871, respectively. The qualitative model established by partial least squares discriminant analysis (PLS-DA) algorithm could accurately classify beef samples as fresh, acceptable or spoiled. The accuracy of the calibration and validation sets were 92.54% and 86.96%, respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.