Abstract

Aims The role of a novel non-contact mapping system (ESI 3000, Endocardial Solutions) to guide radiofrequency catheter ablation of untolerated ventricular tachycardia was investigated in 17 patients; 11 with prior myocardial infarction, three with arrhythmogenic right ventricular dysplasia, and three with idiopathic dilated cardiomyopathy. Methods Twenty-seven monomorphic ventricular tachycardias were induced (mean cycle 320±60ms, range 230–450ms), mapped for 15–20s, and terminated by overdrive pacing or DC shock. Off-line analysis of isopotential activation mapping was performed to identify the diastolic pathway and/or the exit point of the ventricular tachycardia reentry circuit. Radiofrequency current was applied to create a line of block across the diastolic pathway or around the exit point. Results All 27 ventricular tachycardias were mapped with the non-contact system. The endocardial exit point (−7±15ms before QRS onset) was defined in 21/21 postinfarction ventricular tachycardias, in 3/3 arrhythmogenic right ventricular dysplasia and in 1/3 idiopathic dilated cardiomyopathy ventricular tachycardias, respectively. The diastolic pathway (earliest endocardial diastolic activity: −65±49ms before QRS onset) was identified in 17/21 postinfarction ventricular tachycardias, in 1/3 arrhythmogenic right ventricular dysplasia and in 1/3 idiopathic dilated cardiomyopathy ventricular tachycardias, respectively. Catheter ablation was performed in 25/27 ventricular tachycardias (93%) in 15/17 patients (88%): 16/25 ventricular tachycardias (64%) were successfully ablated in 10/17 patients (59%). Catheter ablation was not performed in two patients or proved unsuccessful in five patients. At a follow-up of 15±5 months, there was no recurrence of documented ventricular tachycardia in all 10 patients with successful catheter ablation; in two of them a previously non-documented ventricular tachycardia occurred. A high recurrence of ventricular tachycardia was observed in patients with a failed procedure (5/7: 71%). No major complication or death occurred. Conclusions Non-contact mapping can be effectively used to map and guide radiofrequency catheter ablation of untolerated ventricular tachycardias. Given the favourable acute and clinical long-term results, this approach proves to be more effective in patients with postinfarction ventricular tachycardias, in comparison to patients with arrhythmogenic right ventricular dysplasia and idiopathic dilated cardiomyopathy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.