The article presents the research results of the vibrational characteristics of the designed rotor system, namely, the amplitude-frequency characteristicsare constructed in different frequency ranges and at various unbalanced masses. The main stages of conducting dynamic analysis in ANSYS arehighlighted on the example of harmonic analysis. The critical frequencies for unbalanced rotor are determined at which resonance is observed. Thevalues of the displacement amplitudes at critical frequencies and at the operating frequency under different imbalance values are observed. The plot ofamplitude dependence is constructed on the imbalance magnitude at the pump operating frequency. The obtained values are compared with the maximum allowable gap between the rotor and stator pump parts, and with that in mind, the permissible values of the unbalance values for the designed pump are determined. On the basis of the research, practical recommendations for the pump dynamic balancing have been developed for agiven permissible imbalance magnitude.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Bulletin of the National Technical University «KhPI» Series: Engineering and CAD
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.