Abstract
Initial measurement showed that reading LED lighting used in this experiment produced excessive conducted emissions (CE). EMC filter is needed to suppress the CE noise. The LED light is AC powered through a two-wire cable without ground wire, whereas the EMC filter does have ground. Experiments were conducted to find out the attenuation effect of different filter’s grounding connection methods. Four cases of grounding connections are measured and compared, i.e. unconnected ground, earth-connected ground, chassis-connected ground, and additional ground plate. Measurements showed that chassis-connected ground had the strongest attenuation effect. Also, for the additional ground plate configuration, it turned out that larger plates exhibited stronger attenuation compared to smaller plates. Keywords : LED driver, EMC Filter, grounding, impedance, common mode
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.