Abstract
Two-phase flow, particularly generated in an expansion device, is a primary cause of refrigerant-induced noise in an air-conditioning system. The indoor unit (IDU) of a multi-split air source heat pump (ASHP) for both heating and cooling must include an electric expansion valve (EEV); therefore, consumers have perceived the increased noise. To reduce this noise, we experimentally investigated the two-phase flow and consequent noise by applying a honeycomb and porous metal as a flow conditioner to the EEV in the IDU of a multi-split ASHP. Flow conditioning near the EEV with the honeycomb and porous metal made the two-phase flow steadier and more uniform, leading to reduced noise and frequency variation for the three heat operation modes of a multi-split ASHP. The noise reduction was also verified in the transient operating modes of a real IDU.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.