Abstract

We suggested the model to demonstrate simultaneous switching noise (SSN) coupling to signal and verified experimentally. There are two coupling mechanisms; one is the SSN coupling through the reference changing via, and the other is the SSN coupling through the signal trace. Through measurement and analysis, we confirmed that the worst SSN coupling occurs when strip lines have the signal via changing reference plane with SSN. Furthermore, we demonstrated that the power/ground noise coupling to the signal is reduced by placing the reference changing via at the position where the power/ground cavity impedance is low, or by adjusting the line length between two reference changing vias.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.