An analysis of noise and vibration measurements was carried out for the gear box and the power house panels of the 50 kW Vertical Axis Wind Turbine (V.A.W.T.) operating at Christopher Point on Vancouver Island, B.C. The spectra of noise and vibration signals show strong peaks at the gear mesh frequency and its harmonics even under light load conditions. The sound power radiated from the power house panels is significantly higher than that radiated by the gear box casing. The analysis also indicates misalignment of the pinion shaft or eccentricity of the pinion and errors in the gear tooth profiles. 6 references.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.