Abstract
The description of an adaptive optics (AO) system with no wavefront sensor to correct primary aberrations is presented. This system is based on closed loop software that iteratively analyzes a point source target image on the instrument focal plane and suitably modifies the AO device. The performed tests with a pull-only deformable mirror (DM) have shown that the system works very well, reaching an optimal focusing condition in a few seconds using standard components. Such a system can be conveniently applied in all the fields in which a not very fast optical adaptation is acceptable.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.