Abstract

Cinematic rendering (CR) is a new 3D post-processing technology widely used to produce bone computed tomography (CT) images. This study aimed to evaluate the performance quality of CR in bone CT images using blind quality and noise level evaluations. Bone CT images of the face, shoulder, lumbar spine, and wrist were acquired. Volume rendering (VR), which is widely used in the field of diagnostic medical imaging, was additionally set along with CR. A no-reference-based blind/referenceless image spatial quality evaluator (BRISQUE) and coefficient of variation (COV) were used to evaluate the overall quality of the acquired images. The average BRISQUE values derived from the four areas were 39.87 and 46.44 in CR and VR, respectively. The difference between the two values was approximately 1.16, and the difference between the resulting values increased, particularly in the bone CT image, where metal artifacts were observed. In addition, we confirmed that the COV value improved by 2.20 times on average when using CR compared to VR. This study proved that CR is useful in reconstructing bone CT 3D images and that various applications in the diagnostic medical field will be possible.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.