Abstract

For permanent magnet synchronous motors with parallel branches, circulating currents are induced by a partial demagnetisation fault. The induced currents increase the losses of the motor. Therefore, detecting such a fault becomes possible by analysing the motor losses. This study analyses the effects of the partial demagnetisation fault and defines an index, which is the ratio of increased losses and total losses when the motor is under no-load conditions, to monitor the condition of the rotor magnets. The method is easily implemented and sensitive to the fault. The experimental results validate the effectiveness of the proposed method.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.