Abstract

This study was planned so as to evaluate whether magnetic field exposure has any significant effect on the pentylenetetrazol (PTZ)-induced seizures. Mice were exposed to 50 Hz, 2 G (0.2 mT) magnetic field in glass cages for 1 h. Sham exposure was produced by turning off the current while the animals were in the same exposure volume. Then, PTZ was administered intraperitoneally (i.p.) at a dose of 60 mg/kg and the animals were observed for 30 min. Subsequently, the latency to seizure onset, total seizure duration, the number of seizure episodes and mortality were recorded for each subject. There was no evidence for a significant effect of the 50 Hz magnetic field on the mean number of PTZ induced seizures, seizure latency, total seizure duration and mortality ( P > 0.05). As a conclusion the present study failed to provide any further support for a therapeutic potential of magnetic field.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.