Abstract

An aerobic moving bed biofilm reactor (MBBR) was adopted to treat Lurgi coal gasification waste water (LCGW) in about 10 months. The pollutant load and dissolve oxygen (DO) concentration were adjusted by trying to maximize the accumulation of in the MBBR for LCGW treatment. The highest accumulation proportion was 73.9%, but was not stable with influent chemical oxygen demand (COD) and DO concentrations of around 1000 and 1.5 mg/L, respectively. Around 1500 mg/L of influent COD concentration and 1.5 mg/L of DO concentration were proper operation conditions for the aerobic MBBR to achieve relatively stable accumulation, with ratio at 53% and ratio at just 4.3% in the effluent. More specifically, free ammonia concentration and DO concentration affected accumulation much more obvious than phenols concentration. The activity and quantity of nitrifying bacteria growth in suspended sludge and biofilm of the MBBR were monitored simultaneously to explain the variations of accumulation performance under different operation conditions.