Abstract

In aerated treatment wetlands, oxygen availability is not a limiting factor in sustaining a high level of nitrification in wastewater treatment. In the case of an air blower failure, nitrification would cease, potentially causing adverse effects to the nitrifying bacteria. A field trial was completed investigating nitrification loss when aeration is switched off, and the system recovery rate after the aeration is switched back on. Loss of dissolved oxygen was observed to be more rapid than loss of nitrification. Nitrate was observed in the effluent long after the aeration was switched off (48h+). A complementary modeling study predicted nitrate diffusion out of biofilm over a 48h period. After two weeks of no aeration in the established system, nitrification recovered within two days, whereas nitrification establishment in a new system was previously observed to require 20–45days. These results suggest that once established resident nitrifying microbial communities are quite robust.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.