Abstract
The response of screen-printed thick-films of NiO/TiO/sub 2/ to organic solvent vapours was studied. It was found that these films displayed a significant resistance change in response to the vapours even at room temperature. The sensors displayed an inherent selectivity, proving most sensitive to toluene and propanol vapour; with comparatively low responses exhibited towards ethanol and methanol vapours. Very fast response and recovery times of 9 s and 16 s respectively were recorded for the devices upon exposure to 4000 ppm step changes in propanol concentration.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.