Abstract

Pethidine (PTD), a synthetic opioid prescribed frequently as a painkiller, was included in the WADA list of prohibited substances in sports. The purpose of this study is to investigate the electrochemical determination of PTD using a modified glassy carbon electrode decorated with NiO nanoparticles and decorated graphene oxide nanosheets (NiO-GO/GCE). NiO-GO nanocomposite was created using a straightforward chemical reduction technique. SEM, TEM, and XRD analysis of the structure and morphology pointed to the NiO-GO nanocomposite's effective production. Results showed that NiO-GO/GCE responded to PTD determination in a sensitive, focused, and stable manner with a relatively low detection limit value (3.8 ng/mL) and a wide linear range (0–500 μg/mL) compared to other PTD sensors. Results on the appropriateness and validation of the NiO-GO/GCE for determining PTD content in clinical and human fluid samples illustrated good recoveries between 90.00 % and 99.66 % with a relative standard deviation less than 5.41 %, which were acceptable and corroborated the appropriateness and validation of the NiO-GO/GCE results for PTD sensor in urine samples from healthy athlete volunteers.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.