Abstract
End-stage heart failure is associated with high mortality. Recent developments such as the left ventricular assist device (LVAD) have improved patient outcomes. The HeartMate 3 LVAD is a novel centrifugal pump that was developed to provide hemodynamic support in heart failure patients, either as a bridge-to-transplant (BTT), myocardial recovery, or destination therapy (DT). Our objective was to evaluate the survival rates and LVAD-related complications of the HeartMate 3 LVAD before and after hospital discharge in our center. We retrospectively reviewed all patients implanted with the HeartMate 3 LVAD in our institute between September 2015 and June 2024. Patients who received a Heart Ware Ventricular Assist Device (HVAD) and HeartMate 2 LVAD devices were excluded. The primary endpoint was survival before and after hospital discharge. The secondary endpoints included an incidence of serious LVAD adverse events (bleeding, major infection, hemolysis, device thrombosis and malfunction, and neurological dysfunction) and the causes of re-admission along the follow-up period. A total of 48 consecutive HeartMate 3 LVAD patients were enrolled in this study. The mean age was 56.1 ± 10.6 years. A total of 72.9% of patients received LVAD therapy as a BTT, 14.6% as DT, 10.4% as a bridge-to-decision, and 2.1% as a bridge-to-recovery. A total of 85.4% of patients were discharged after implantation. The main cause for in-hospital mortality was right ventricular failure (8.3%), followed by stroke, abdominal bleeding, and multi-organ failure (2.1% each). One patient (2.1%) had successful heart transplantation, 26 patients (63.4%) are still on LVAD support, and 11 (26.8%) patients have died during follow-up. The main cause of mortality after hospital discharge was sepsis, which occurred in 9.8% of patients, followed by right ventricular failure, non-LVAD-related causes, unknown causes with two (4.9%) cases each, and one case of fatal stroke (2.4%). During the follow-up, there was no need for LVAD replacement. HeartMate 3 LVAD is associated with excellent in-hospital survival rates in patients with end-stage heart failure. Right ventricular failure was the main cause of death before hospital discharge, whereas sepsis was the main cause of death after hospital discharge.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.