Abstract

The paper describes about a newly-developed adaptive noise absorption control (AAC) technology I for fan noise reduction and about proof test results of the technology. The AAC technology adaptively controls the reactance part of acoustic impedance of duct liners with mobile reflective plates and large acoustic chambers, absorbs fan tones and broadband noise together, and achieves larger overall fan noise reduction over a wide fan speed range. For actual proof of the technology, adaptive duct liner I was made on trial basis and was examined. The test result clarifies that the duct liner I could reduce fan noise larger than O.A. SPL 10dB (A) at max fan speed of 6000rpm, including reduction of low frequency noise and fundamental BPF tone and harmonics of 18dB at maximum. In response to fan speed change, the reflective plate movement control could achieve the large peak frequency shift and peak level increase in the acoustic absorption spectra, and could reduce fan noise larger than O.A. SPL 9dB (A) over the fan speed range from 1000 to 6000rpm.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.