Abstract

Over the past few years, the South Island of New Zealand has been subject to significant sequences of earthquake shaking. In particular, 2010-2011 events affected the city of Christchurch resulting in large scale demolition of buildings. Also, the recent and continuing 11/2016 events caused severe damage in the countryside, in small towns, and moderate damage further afield. This paper describes “low damage construction” methods being used in NZ, and especially in the Christchurch rebuild, to limit the possibility of building demolition in future large seismic events. The buildings used in the Christchurch rebuild are generally supported by structural steel framing. These steel buildings include BRB systems, EBF systems with replaceable active links, rocking systems, base isolation using friction pendulum systems and/or lead-rubber dissipaters, RBS beams, lead extrusion dissipaters, yielding flexural dissipaters, and friction connections. Concerns about a number of currently used systems are discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.