Abstract
Scanning Spreading Resistance Microscopy (SSRM) is successfully applied to investigate failing nLDMOS test devices that exhibit a lowered break down voltage (BVDSS) in electrical test. Cross-sectional, two-dimensional maps of the local sample resistivity from fail and reference (pass) devices reveal significant differences of the dopant concentration in individual, specific regions. This important information enables unambiguous identification of the root cause of the device failure to be dopant related. Furthermore, from a set of hypothesis, which explains the failed electrical test, SSRM results confirm exactly one and rule out the other. These are two important steps towards root cause identification. Since a relative comparison of fail and pass SSRM scans is sufficient for this failure analysis, an extensive data calibration for the absolute dopant concentration by means of additional SSRM measurements on test samples with known dopant concentration is not required. The ability of SSRM to prove or disprove miscellaneous fail hypothesis even without data calibration makes this method a very powerful tool for analysis of dopant related failure types.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.