Abstract

Salvage total hip arthroplasty for failed Dynamic hip screw fixation has widely been advocated as a viable treatment option with successful functional outcomes. However, when revising a dynamic hip screw, removal of the lag screw can pose problems in terms of difficulty and risk of iatrogenic fractures. This is because the lag screw is not reverse-cutting and therefore a large torque is generated which can lead to such fractures. We report on a series of eight cases in which we excised the femoral head with the lag screw in situ. We recommend this technique as a safe and effective method to reduce the risk of iatrogenic fractures.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.