Abstract
An early and accurate diagnosis of a specific DNA mutations has a decisive role for effective treatment. Especially, when an immediate decision on treatment most needs to be made, the rapid and precise confirmation of clinical findings is vital. Herein, we show a new strategy for the gene mutation (BRAF c.1799T>A; p. V600E) identification using highly SERS-active and reproducible SERS substrate (photo-etched GaN covered with a thin layer of sputtered gold) and surface enhanced Raman scattering (SERS) spectroscopy. The detection is based on the conformation change (gauche → trans) of the alkanethiol linker modifying the capture DNA during the hybridization process. The value of the intensity ratio of the ν(C–S) bands of the trans and gauche conformer higher than 1.0 indicated the presence of mutation. The demonstrated new DNA SERS (bio)sensor is characterized by the low detection limit at the level of pg μL–1, wide analytical range from 6.75 pg μL–1 to 67.5 ng μL–1 and high selectivity. The proposed bioactive platforms, based on nanostructured GaN substrates modified with thiolated ssDNA (single stranded DNA) can be successfully used in the analysis of clinical samples.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.